7355 código(s) en esta categoría. Página 104 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
Drive motor A reports temperature above the safe operating threshold. Sustained high load, cooling failure, or…
The ECM detects a circuit fault on the drive motor b temperature sensor. Reading cannot be used reliably for c…
The ECM detects a circuit range/performance fault on the drive motor b temperature sensor. Reading cannot be u…
The ECM detects a circuit low fault on the drive motor b temperature sensor. Reading cannot be used reliably f…
The ECM detects a circuit high fault on the drive motor b temperature sensor. Reading cannot be used reliably …
The ECM detects a circuit intermittent fault on the drive motor b temperature sensor. Reading cannot be used r…
Drive motor B reports temperature above the safe operating threshold. The drive motor's position, current and …
The ECM detects a circuit fault on the generator temperature sensor. Reading cannot be used reliably for contr…
The ECM detects a circuit range/performance fault on the generator temperature sensor. Reading cannot be used …
The ECM detects a circuit low fault on the generator temperature sensor. Reading cannot be used reliably for c…
The ECM detects a circuit high fault on the generator temperature sensor. Reading cannot be used reliably for …
The ECM detects a circuit intermittent fault on the generator temperature sensor. Reading cannot be used relia…
Generator A reports temperature above the safe operating threshold.…
The inverter for drive motor A does not produce expected output torque or commutation timing within tolerance,…
The drive motor B inverter reports junction temperature above the protection threshold. Sustained high load or…
El motor eléctrico no puede arrancar el motor de combustión en el sistema híbrido.…
El sistema que precalienta la batería en climas fríos no funciona correctamente.…
Electrical fault on the resolver or encoder used to determine rotor position of drive motor A. Position is ess…
The drive motor A rotor position signal is implausible relative to motor speed and torque commands, indicating…
The drive motor A rotor position sensor reports a circuit high fault. Phase commutation cannot be controlled r…
The drive motor A rotor position sensor reports a circuit intermittent fault. Phase commutation cannot be cont…
The drive motor A rotor position sensor reports a circuit overspeed fault. Phase commutation cannot be control…
The drive motor B rotor position sensor reports a circuit fault. Phase commutation cannot be controlled reliab…
The drive motor B rotor position sensor reports a circuit range/performance fault. Phase commutation cannot be…