7355 código(s) en esta categoría. Página 114 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
The ECM detects a circuit range/performance fault on the hybrid/ev battery pack voltage sense d circuit. Readi…
The ECM detects a circuit low fault on the hybrid/ev battery pack voltage sense d circuit. Reading cannot be u…
The ECM detects a circuit high fault on the hybrid/ev battery pack voltage sense d circuit. Reading cannot be …
Electrical fault on the phase U current sensor of the generator/MG2 used in series-parallel hybrid systems.…
The BMS detects a generic fault on the voltage measurement of HV battery A. Cell-group voltage monitoring is t…
The voltage measurement of HV battery A fluctuates beyond the expected window. Loose connection or unstable ce…
La temperatura del inversor del motor eléctrico es demasiado alta.…
The voltage of HV battery A exceeds the expected window. Charging overvoltage or sense fault. Cell-group volta…
The BMS detects a generic fault on the voltage measurement of HV battery B. Cell-group voltage monitoring is t…
The voltage measurement of HV battery B fluctuates beyond the expected window. Loose connection or unstable ce…
The voltage of HV battery B is below the expected window. Cell-group depleted, deeply aged, or sense fault.…
The voltage of HV battery B exceeds the expected window. Charging overvoltage or sense fault. Cell-group volta…
The BMS detects a generic fault on the voltage measurement of HV battery C. Cell-group voltage monitoring is t…
The voltage measurement of HV battery C fluctuates beyond the expected window. Loose connection or unstable ce…
The voltage of HV battery C is below the expected window. Cell-group depleted, deeply aged, or sense fault.…
The voltage of HV battery C exceeds the expected window. Charging overvoltage or sense fault. Cell-group volta…
The BMS detects a generic fault on the voltage measurement of HV battery D. Cell-group voltage monitoring is t…
The voltage measurement of HV battery D fluctuates beyond the expected window. Loose connection or unstable ce…
The voltage of HV battery D is below the expected window. Cell-group depleted, deeply aged, or sense fault.…
The voltage of HV battery D exceeds the expected window. Charging overvoltage or sense fault. Cell-group volta…
The high-voltage service disconnect circuit reports a circuit condition. Safe HV disconnection state cannot be…
The high-voltage service disconnect circuit reports a circuit performance condition. Safe HV disconnection sta…
The high-voltage service disconnect circuit reports a circuit low condition. Safe HV disconnection state canno…
The high-voltage service disconnect circuit reports a circuit high condition. Safe HV disconnection state cann…