7355 código(s) en esta categoría. Página 160 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
The IMT valve on bank 2 is mechanically stuck closed — short-runner mode is unavailable, top-end power suffers…
The intake-manifold tuning (IMT) valve on bank 2 is mechanically stuck open — long-runner mode is unavailable,…
The electronic throttle on bank 1 is jammed by ice — typical at very low ambient temperatures with high humidi…
At idle, the relationship between MAP/MAF and throttle position does not match the calibrated map — typically …
At higher load, the relationship between MAP/MAF and throttle position does not match the calibrated map — typ…
A general electrical fault is reported on the IMT valve position sensor at bank 1 — open, short, or out of pla…
IMT valve position sensor at bank 1 reads in range but plausibility check fails — value sticks or does not mat…
IMT position sensor at bank 1 reads below lower plausibility — short to ground. The intake manifold runner con…
IMT position sensor at bank 1 reads above upper plausibility — open signal or short to B+. The intake manifold…
IMT position sensor at bank 1 signal is unstable — connector or harness issue. The intake manifold runner cont…
A general electrical fault is reported on the IMT valve position sensor at bank 2 — open, short, or out of pla…
IMT valve position sensor at bank 2 reads in range but plausibility check fails — value sticks or does not mat…
IMT position sensor at bank 2 reads below lower plausibility — short to ground. The intake manifold runner con…
IMT position sensor at bank 2 reads above upper plausibility — open signal or short to B+. The intake manifold…
IMT position sensor at bank 2 signal is unstable — connector or harness issue. The intake manifold runner cont…
The ECU has concluded that the AdBlue/DEF in the tank does not meet specification. Diagnosed by comparing expe…
The pre-catalyst EGT sensor on bank 1 returns a value that does not match the expected temperature curve under…
The EGT sensor at bank 1 sensor 1 signal jumps or drops out intermittently — typically a connector or chafed w…
The EGT sensor at bank 2 sensor 1 reads in range but plausibility check fails — slow response, stuck reading, …
The EGT sensor at bank 2 sensor 1 signal jumps or drops out intermittently — typically a connector or chafed w…
The bank 1 sensor 2 EGT reading deviates from the expected ratio against the upstream EGT sensor or modeled ex…
The EGT sensor at bank 1 sensor 2 signal jumps or drops out intermittently — typically a connector or chafed w…
The EGT sensor at bank 2 sensor 2 reads in range but plausibility check fails — slow response, stuck reading, …