Motor (P)
Cylinder 10 second-injector (B) drive line stuck high — short to B+. A flow-deviating injector throws off cyli…
Cylinder 11 second-injector (B) drive line stuck low — short to ground. A flow-deviating injector throws off c…
Cylinder 11 second-injector (B) drive line stuck high — short to B+. A flow-deviating injector throws off cyli…
Cylinder 12 second-injector (B) drive line stuck low — short to ground. A flow-deviating injector throws off c…
Cylinder 12 second-injector (B) drive line stuck high — short to B+. A flow-deviating injector throws off cyli…
The secondary fuel control loop B on bank 1 reports a lean condition outside idle. On dual-injection systems (…
The secondary fuel control loop B on bank 1 reports a rich condition outside idle.…
The secondary fuel control loop B on bank 2 reports a lean condition outside idle. On dual-injection systems (…
The secondary fuel control loop B on bank 2 reports a rich condition outside idle.…
Secondary fuel control loop B reports a lean condition at idle on bank 1. Idle is sensitive to vacuum leaks si…
Secondary fuel control loop B reports a lean condition at idle on bank 2. Idle is sensitive to vacuum leaks si…
The secondary fuel control loop B reports a rich condition at idle on bank 2. Idle rich often means injectors …
Secondary fuel control loop B on bank 1 reports a lean condition at higher load. Lean at high load typically p…
Secondary fuel control loop B on bank 2 reports a lean condition at higher load. Lean at high load typically p…
The secondary fuel control loop B reports a rich condition at higher load on bank 2. Rich at high load typical…
The NOx sensor on bank 1 — typically upstream of the SCR catalyst — does not communicate or sends an invalid s…
The bank 1 NOx sensor reports values outside the plausibility window against modeled NOx and the downstream se…
The NOx sensor signal on bank 1 is below the lower limit. Either short to ground on the analog return, sensor …
The NOx sensor signal on bank 1 is above the upper limit — short to supply, open ground, or a sensor that fail…
The bank 1 NOx sensor signal drops out intermittently. Typical cause is a marginal connector, harness chafing …
The heater inside the bank 1 NOx sensor cannot be controlled — open, short, or failed driver. Without proper h…
A general electrical fault on the bank 2 NOx sensor circuit. NOx sensors are smart sensors with a CAN/LIN inte…