Motor (P)
The TCM detects an electrical fault on transmission pressure control solenoid H. Hydraulic pressure cannot be …
Pressure control solenoid H shows intermittent electrical or hydraulic faults. Loose connector or marginal coi…
The TCM detects an open circuit in the control wiring of pressure control solenoid H. No current flows when th…
The current through pressure control solenoid H does not match the commanded value within tolerance. Coil resi…
Voltage on the pressure control solenoid H control line is below the expected window. Wiring faults of this ki…
Voltage on the pressure control solenoid H control line is above the expected window. Wiring faults of this ki…
A general fault in pressure control solenoid J. Detected via electrical resistance, response to commanded duty…
Pressure control solenoid J is commanded on but does not produce the expected pressure. Spool stuck closed or …
Pressure control solenoid J stays in the activated state when commanded off. Affected hydraulic circuit stays …
The TCM detects an electrical fault on transmission pressure control solenoid J. Hydraulic pressure cannot be …
Pressure control solenoid J shows intermittent electrical or hydraulic faults. Loose connector or marginal coi…
The TCM detects an open circuit in the control wiring of pressure control solenoid J. No current flows when th…
The current through pressure control solenoid J does not match the commanded value within tolerance. Coil resi…
Voltage on the pressure control solenoid J control line is below the expected window. Wiring faults of this ki…
Voltage on the pressure control solenoid J control line is above the expected window. Wiring faults of this ki…
A general fault in pressure control solenoid K. Detected via electrical resistance, response to commanded duty…
Pressure control solenoid K is commanded on but does not produce the expected pressure. Spool stuck closed or …
Pressure control solenoid K stays in the activated state when commanded off. Affected hydraulic circuit stays …
The TCM detects an electrical fault on transmission pressure control solenoid K. Hydraulic pressure cannot be …
Pressure control solenoid K shows intermittent electrical or hydraulic faults. Loose connector or marginal coi…
The TCM detects an open circuit in the control wiring of pressure control solenoid K. No current flows when th…
The current through pressure control solenoid K does not match the commanded value within tolerance. Coil resi…
Voltage on the pressure control solenoid K control line is below the expected window. Wiring faults of this ki…
Voltage on the pressure control solenoid K control line is above the expected window. Wiring faults of this ki…