Motor (P)
The ion current signal from cylinder 7 is outside the expected range for combustion conditions. Combustion qua…
Ion current from cylinder 7 is below the expected window. Spark plug fouled, signal wire shorted to ground, or…
Ion current from cylinder 7 is above the expected window. Cross-coupled signal, biased reference, or sensor fa…
The ECM cannot read a valid ion current signal from cylinder 8. Ion current sensing relies on the spark plug a…
The ion current signal from cylinder 8 is outside the expected range for combustion conditions. Combustion qua…
Ion current from cylinder 8 is below the expected window. Spark plug fouled, signal wire shorted to ground, or…
Ion current from cylinder 8 is above the expected window. Cross-coupled signal, biased reference, or sensor fa…
The ECM cannot read a valid ion current signal from cylinder 9. Ion current sensing relies on the spark plug a…
The ion current signal from cylinder 9 is outside the expected range for combustion conditions. Combustion qua…
Ion current from cylinder 9 is below the expected window. Spark plug fouled, signal wire shorted to ground, or…
Ion current from cylinder 9 is above the expected window. Cross-coupled signal, biased reference, or sensor fa…
The ECM cannot read a valid ion current signal from cylinder 10. Ion current sensing relies on the spark plug …
The ion current signal from cylinder 10 is outside the expected range for combustion conditions. Combustion qu…
Ion current from cylinder 10 is below the expected window. Spark plug fouled, signal wire shorted to ground, o…
Ion current from cylinder 10 is above the expected window. Cross-coupled signal, biased reference, or sensor f…
The ECM cannot read a valid ion current signal from cylinder 11. Ion current sensing relies on the spark plug …
The ion current signal from cylinder 11 is outside the expected range for combustion conditions. Combustion qu…
Ion current from cylinder 11 is below the expected window. Spark plug fouled, signal wire shorted to ground, o…
Ion current from cylinder 11 is above the expected window. Cross-coupled signal, biased reference, or sensor f…
The ECM cannot read a valid ion current signal from cylinder 12. Ion current sensing relies on the spark plug …
The ion current signal from cylinder 12 is outside the expected range for combustion conditions. Combustion qu…
Ion current from cylinder 12 is below the expected window. Spark plug fouled, signal wire shorted to ground, o…
Ion current from cylinder 12 is above the expected window. Cross-coupled signal, biased reference, or sensor f…
The ECM detects a generic fault on the supply voltage circuit of the ion sense module. The module can no longe…