7355 código(s) en esta categoría. Página 250 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
The hybrid control module detects a generic fault on the engine disconnect clutch pressure sensor circuit. Eng…
The engine disconnect clutch pressure signal does not match plausibility checks against actuator commands. Sen…
Voltage on the engine disconnect clutch pressure sensor signal line is below the expected window. Wire shorted…
Voltage on the engine disconnect clutch pressure sensor signal line is above the expected window. Wire shorted…
The engine disconnect clutch pressure sensor signal drops out or jumps intermittently. Loose connector or nois…
The control circuit of the engine disconnect clutch actuator drops out intermittently. Loose connector or vibr…
The exhaust pressure measured on bank 1 exceeds the calibrated maximum. Common causes are clogged DPF, restric…
The exhaust pressure measured on bank 2 exceeds the calibrated maximum. Common causes are clogged DPF, restric…
The exhaust pressure measured on bank 1 falls below the calibrated minimum. Common causes are leaks upstream o…
The exhaust pressure measured on bank 2 falls below the calibrated minimum. Common causes are leaks upstream o…
Long-term plausibility checks show that the front oxygen sensor on bank 1 reacts too slowly or stays too close…
The rear oxygen sensor on bank 1 does not show the expected slow steady-state behaviour after the catalyst. Ei…
The optional third oxygen sensor on bank 1 (typically downstream of a second catalyst) returns implausible val…
The front oxygen sensor on bank 2 reacts too slowly or shows insufficient signal swing during closed-loop fuel…
The rear oxygen sensor on bank 2 shows abnormal behaviour during long-term plausibility evaluation. Often a si…
The third oxygen sensor on bank 2 (after a second catalyst stage on some vehicles) returns implausible values.…
The fourth oxygen sensor on bank 1, where present, returns implausible values during long-term plausibility ev…
The fourth oxygen sensor on bank 2 returns values outside the expected long-term performance window during pla…
The ECM detects a negative voltage on the signal line of oxygen sensor 3 on bank 1. This is unusual for narrow…
The ECM detects a negative voltage on the signal line of oxygen sensor 1 on bank 2. This is unusual for narrow…
The ECM detects a generic fault on the secondary manifold absolute pressure sensor (MAP B). Air load estimatio…
The MAP B signal does not correlate with TPS, MAF, or RPM as expected. Vacuum leak, restricted port, or sensor…
Voltage on the MAP B signal line is below the expected window. Wire shorted to ground or sensor short.…
Voltage on the MAP B signal line is above the expected window. Wire shorted to B+ or sensor open. Wiring fault…