Motor (P)
The outlet temperature signal of alternative fuel vaporizer B does not match plausibility checks against fuel …
Voltage on the outlet temperature sensor signal line of alternative fuel vaporizer B is below the expected win…
Voltage on the outlet temperature sensor signal line of alternative fuel vaporizer B is above the expected win…
The outlet temperature sensor signal of alternative fuel vaporizer B drops out or jumps intermittently. Loose …
The AFCM detects a generic fault on the outlet temperature sensor of alternative fuel vaporizer C. Vaporizatio…
The outlet temperature signal of alternative fuel vaporizer C does not match plausibility checks against fuel …
Voltage on the outlet temperature sensor signal line of alternative fuel vaporizer C is below the expected win…
Voltage on the outlet temperature sensor signal line of alternative fuel vaporizer C is above the expected win…
The outlet temperature sensor signal of alternative fuel vaporizer C drops out or jumps intermittently. Loose …
The AFCM detects a generic fault on the level sensor of alternative fuel tank B. Tank fill level cannot be dis…
The level signal of alternative fuel tank B does not match plausibility checks against consumption and refuel …
Voltage on the level sensor signal line of alternative fuel tank B is below the expected window. Wire shorted …
Voltage on the level sensor signal line of alternative fuel tank B is above the expected window. Wire shorted …
The level sensor signal of alternative fuel tank B drops out or jumps intermittently. Loose connector or vibra…
The AFCM detects a generic fault on the level sensor of alternative fuel tank C. Tank fill level cannot be dis…
The level signal of alternative fuel tank C does not match plausibility checks against consumption and refuel …
Voltage on the level sensor signal line of alternative fuel tank C is below the expected window. Wire shorted …
Voltage on the level sensor signal line of alternative fuel tank C is above the expected window. Wire shorted …
The level sensor signal of alternative fuel tank C drops out or jumps intermittently. Loose connector or vibra…
The AFCM detects a generic fault on the pressure sensor at the inlet of the alternative fuel rail pressure reg…
The inlet pressure signal of the alternative fuel rail pressure regulator does not match plausibility checks a…
Voltage on the inlet pressure sensor signal line of the alternative fuel rail pressure regulator is below the …
Voltage on the inlet pressure sensor signal line of the alternative fuel rail pressure regulator is above the …
The inlet pressure sensor signal of the alternative fuel rail pressure regulator drops out or jumps intermitte…