7355 código(s) en esta categoría. Página 288 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
The signals of the fuel temperature sensors A and B do not correlate within the calibrated tolerance. One sens…
The fan 1 control module reports temperature above the protection threshold. Sustained operation, high ambient…
The fan 1 control module response does not match the calibrated profile. Internal self-tests fail or output dr…
The supply voltage circuit of the fan 1 control module reports a fault. Module may not start or operate correc…
The fan 2 control module reports temperature above the protection threshold. Sustained operation, high ambient…
The fan 2 control module response does not match the calibrated profile. Internal self-tests fail or output dr…
The supply voltage circuit of the fan 2 control module reports a fault. Module may not start or operate correc…
The engine disconnect clutch does not deliver the expected mechanical engagement or release. Friction surface …
The ECM detects a circuit fault on the engine oil pressure sensor/switch c circuit. Reading cannot be used rel…
The ECM detects a circuit low fault on the engine oil pressure sensor/switch c circuit. Reading cannot be used…
The ECM detects a circuit high fault on the engine oil pressure sensor/switch c circuit. Reading cannot be use…
The ECM detects a range/performance fault on the engine oil pressure sensor/switch c. Reading cannot be used r…
The current sensor for starter/generator phase X reports voltage above the expected window. Indicates short to…
The current sensor for starter/generator phase Y reports voltage above the expected window. Indicates short to…
The current sensor for starter/generator phase Z reports voltage above the expected window. Indicates short to…
The current sensor for starter/generator phase X reports voltage below the expected window. Indicates short to…
The current sensor for starter/generator phase Y reports voltage below the expected window. Indicates short to…
The current sensor for starter/generator phase Z reports voltage below the expected window. Indicates short to…
The current measurement on starter/generator phase X drops out or jumps intermittently. Loose connector or vib…
The current measurement on starter/generator phase Y drops out or jumps intermittently. Loose connector or vib…
The current measurement on starter/generator phase Z drops out or jumps intermittently. Loose connector or vib…
The current measurement on starter/generator phase U drops out or jumps intermittently. Loose connector or vib…
The current measurement on starter/generator phase V drops out or jumps intermittently. Loose connector or vib…
The current measurement on starter/generator phase W drops out or jumps intermittently. Loose connector or vib…