7355 código(s) en esta categoría. Página 290 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
The battery charger B cooling system does not maintain target temperatures under load. Coolant flow reduced, f…
The high-voltage interlock circuit of battery charging system B reports a circuit/open condition. Safety inter…
The high-voltage interlock circuit of battery charging system B reports a circuit performance condition. Safet…
The high-voltage interlock circuit of battery charging system B reports a circuit low condition. Safety interl…
The high-voltage interlock circuit of battery charging system B reports a circuit high condition. Safety inter…
The high-voltage interlock circuit of battery charging system B reports a circuit intermittent/erratic conditi…
The ECM detects a circuit fault on the battery charger b coupler lock position sensor circuit. Reading cannot …
The ECM detects a range/performance fault on the battery charger b coupler lock position sensor circuit. Readi…
The ECM detects a circuit low fault on the battery charger b coupler lock position sensor circuit. Reading can…
The ECM detects a circuit high fault on the battery charger b coupler lock position sensor circuit. Reading ca…
The ECM detects a circuit intermittent/erratic fault on the battery charger b coupler lock position sensor cir…
The current sensor for starter/generator phase X reports a circuit fault. Phase current measurement is unrelia…
The current sensor for starter/generator phase X reports a circuit range/performance fault. Phase current meas…
The current sensor for starter/generator phase Y reports a circuit fault. Phase current measurement is unrelia…
The current sensor for starter/generator phase Y reports a circuit range/performance fault. Phase current meas…
The current sensor for starter/generator phase Z reports a circuit fault. Phase current measurement is unrelia…
The current sensor for starter/generator phase Z reports a circuit range/performance fault. Phase current meas…
The starter/generator excitation current control reports a generic fault.…
The starter/generator excitation current is below the expected window.…
The starter/generator excitation current is above the expected window. Indicates winding short or driver fault…
The starter/generator excitation current drops out or jumps intermittently. Loose connector or unstable driver…
The phase X, Y, and Z current sensors of the starter/generator do not correlate within the calibrated toleranc…
The starter/generator rotor position sensors do not correlate with the calculated electrical angle within tole…
The ECM detects that the installed particulate filter B does not match the expected type or specification. Wro…