7355 código(s) en esta categoría. Página 5 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
Heater resistance out of range on bank 2 sensor 3. The sensor heater warms the element to operating temperatur…
Generic electrical fault in the heater control of bank 2 sensor 3. The sensor heater warms the element to oper…
Heater control voltage of bank 2 sensor 3 below the expected range. The sensor heater warms the element to ope…
Heater control voltage of bank 2 sensor 3 above the expected range. The sensor heater warms the element to ope…
The air-assist injector control system (used on some lean-burn or direct-injection engines to atomize fuel wit…
Control voltage of the air-assist injector valve is below the expected range — short to ground or low-resistan…
Control voltage of the air-assist injector valve is above the expected range — short to power or open ground. …
The ECU detects implausibility between throttle position and the airflow or intake manifold pressure measured.…
At engine cranking or key-on the intake manifold pressure should equal barometric pressure within tolerance. T…
The expected relationship between manifold absolute pressure (MAP) and mass airflow (MAF) on bank 1 is violate…
The relationship between manifold absolute pressure and exhaust back pressure is implausible. One of the two p…
The relationship between manifold absolute pressure and turbocharger inlet pressure is implausible. Indicates …
The relationship between barometric pressure and turbo inlet pressure (bank 1) is implausible — at engine off …
Supply voltage to boost control actuator A below expected range. Same as P005E but on actuator A. Boost contro…
Supply voltage to boost control actuator A above expected range. Same as P005F but on actuator A. Boost contro…
Generic electrical fault in the ambient air temperature sensor A circuit. Used by the ECU for cold-start corre…
The ambient air temperature reading is electrically valid but implausible compared to other temperature source…
Ambient air temperature sensor A signal voltage below the expected range — typically a short to ground.…
Ambient air temperature sensor A signal voltage above the expected range — typically open circuit (broken wire…
Intermittent dropouts or noise on the ambient air temperature sensor A signal — typically a loose connector or…
Generic electrical fault on the intake-valve control solenoid for bank 1 (used to switch valve lift, deactivat…
Intake valve solenoid bank 1 control voltage below expected range. Short to ground or low-resistance fault.…
Intake valve solenoid bank 1 control voltage above expected range. Short to power or open ground. Wiring fault…
Generic electrical fault on the exhaust-valve control solenoid for bank 1. The exhaust control valve modulates…