7355 código(s) en esta categoría. Página 92 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
The TCM monitors the output side of its power relay; when the sense voltage is below threshold while relay is …
The TCM detects voltage on the relay sense line above threshold while relay is commanded open, indicating rela…
The sense feedback from the TCM power relay drops out intermittently. Loose connector or oxidised relay contac…
The TCM detects that more than one gear element is engaged simultaneously. Risk of transmission lock-up - seve…
The TCM detects slipping in a clutch or band element. Output speed does not match the calculated value for the…
The transmission shift time is shorter than the calibrated minimum. Risk of harsh engagement and shock loads.…
The transmission shift time exceeds the calibrated maximum. Possible hydraulic restriction, weak solenoid, or …
The TCM detects deteriorated transmission fluid based on temperature exposure history or sensor measurement. F…
Voltage on the transmission control system MIL request circuit is below the expected window. Wire shorted to g…
Voltage on the transmission control system MIL request circuit is above the expected window. Wire shorted to B…
The gear lever X-axis position sensor 2 reports a circuit fault. Redundant selector position channel is unreli…
The gear lever X-axis position sensor 2 reports a circuit range/performance fault. Redundant selector position…
The gear lever X-axis position sensor 2 reports a circuit low fault. Redundant selector position channel is un…
The gear lever X-axis position sensor 2 reports a circuit high fault. Redundant selector position channel is u…
The gear lever X-axis position sensor 2 reports a circuit intermittent/erratic fault. Redundant selector posit…
The gear lever Y-axis position sensor 2 reports a circuit fault. Redundant selector position channel is unreli…
The gear lever Y-axis position sensor 2 reports a circuit range/performance fault. Redundant selector position…
The gear lever Y-axis position sensor 2 reports a circuit low fault. Redundant selector position channel is un…
The gear lever Y-axis position sensor 2 reports a circuit high fault. Redundant selector position channel is u…
The gear lever Y-axis position sensor 2 reports a circuit intermittent/erratic fault. Redundant selector posit…
The signals of the gear lever X-axis position sensors 1 and 2 do not correlate within the calibrated tolerance…
The signals of the gear lever Y-axis position sensors 1 and 2 do not correlate within the calibrated tolerance…
The signals of multiple gear lever position sensors do not correlate within the calibrated tolerance.…
The clutch pedal position sensor A reports a circuit/open fault. Pedal position cannot be measured reliably.…