Saltar al contenido
URed CAN (U)

Códigos de Red CAN (U)

1230 código(s) en esta categoría. Página 48 de 52. Selecciona uno para ver el diagnóstico detallado.

U3511Crítica

High Voltage System Interlock Circuit B

Red (U)

Generic fault on the second high-voltage interlock loop (HVIL) circuit. The interlock detects whether HV conne

Ver diagnóstico
U3512Crítica

High Voltage System Interlock Circuit B Performance

Red (U)

HVIL loop B is electrically OK but timing/pattern does not match expected behavior — possibly intermittent con

Ver diagnóstico
U3513Crítica

High Voltage System Interlock Circuit B Low

Red (U)

HVIL loop B voltage below expected range — short to ground in the interlock wiring. A communication loss with

Ver diagnóstico
U3514Crítica

High Voltage System Interlock Circuit B High

Red (U)

HVIL loop B voltage above expected range — open or short to power. A communication loss with this module break

Ver diagnóstico
U3515Crítica

High Voltage System Interlock Circuit C

Red (U)

Generic fault on HVIL loop C. See U3511 for general HVIL behavior. A communication loss with this module break

Ver diagnóstico
U3516Crítica

High Voltage System Interlock Circuit C Performance

Red (U)

HVIL loop C timing/pattern does not match expected behavior. A communication loss with this module breaks any

Ver diagnóstico
U3517Crítica

High Voltage System Interlock Circuit C Low

Red (U)

HVIL loop C voltage below expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U3518Crítica

High Voltage System Interlock Circuit C High

Red (U)

HVIL loop C voltage above expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U3519Crítica

High Voltage System Interlock Circuit D

Red (U)

Generic fault on HVIL loop D. A communication loss with this module breaks any function relying on its data —

Ver diagnóstico
U351ACrítica

High Voltage System Interlock Circuit D Performance

Red (U)

HVIL loop D timing/pattern does not match expected behavior. A communication loss with this module breaks any

Ver diagnóstico
U351BCrítica

High Voltage System Interlock Circuit D Low

Red (U)

HVIL loop D voltage below expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U351CCrítica

High Voltage System Interlock Circuit D High

Red (U)

HVIL loop D voltage above expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U351DCrítica

High Voltage System Interlock Circuit E

Red (U)

Generic fault on HVIL loop E. A communication loss with this module breaks any function relying on its data —

Ver diagnóstico
U351ECrítica

High Voltage System Interlock Circuit E Performance

Red (U)

HVIL loop E timing/pattern does not match expected behavior. A communication loss with this module breaks any

Ver diagnóstico
U351FCrítica

High Voltage System Interlock Circuit E Low

Red (U)

HVIL loop E voltage below expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U3520Crítica

High Voltage System Interlock Circuit E High

Red (U)

HVIL loop E voltage above expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U3521Crítica

High Voltage System Interlock Circuit F

Red (U)

Generic fault on HVIL loop F. A communication loss with this module breaks any function relying on its data —

Ver diagnóstico
U3522Crítica

High Voltage System Interlock Circuit F Performance

Red (U)

HVIL loop F timing/pattern does not match expected behavior. A communication loss with this module breaks any

Ver diagnóstico
U3523Crítica

High Voltage System Interlock Circuit F Low

Red (U)

HVIL loop F voltage below expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U3524Crítica

High Voltage System Interlock Circuit F High

Red (U)

HVIL loop F voltage above expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U3525Crítica

High Voltage System Interlock Circuit G

Red (U)

Generic fault on HVIL loop G. A communication loss with this module breaks any function relying on its data —

Ver diagnóstico
U3526Crítica

High Voltage System Interlock Circuit G Performance

Red (U)

HVIL loop G timing/pattern does not match expected behavior. A communication loss with this module breaks any

Ver diagnóstico
U3527Crítica

High Voltage System Interlock Circuit G Low

Red (U)

HVIL loop G voltage below expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico
U3528Crítica

High Voltage System Interlock Circuit G High

Red (U)

HVIL loop G voltage above expected range. A communication loss with this module breaks any function relying on

Ver diagnóstico