Skip to content
UNetwork (U)

Codes Network (U)

1230 code(s) in this category. Page 45 of 52. Select one to see the detailed diagnosis.

U3000Crítica

Control Module

Red (U)

Generic fault on the control module itself — internal self-diagnostic flagged a problem with computation, memo

View diagnosis
U3001Moderada

Control Module Improper Shutdown Performance

Red (U)

The control module did not complete its shutdown sequence cleanly — power was lost before housekeeping (saving

View diagnosis
U3002Moderada

Vehicle Identification Number

Red (U)

The control module reports a problem with the stored Vehicle Identification Number (VIN) — missing, mismatched

View diagnosis
U3003Moderada

Battery Voltage

Red (U)

The control module detected battery voltage outside its acceptable operating window. Either too low (drained b

View diagnosis
U3004Moderada

Accessory Power Relay

Red (U)

Fault on the accessory power relay that switches power to comfort/accessory loads (radio, infotainment, etc.)

View diagnosis
U3005Moderada

Retained Accessory Power

Red (U)

Fault on the retained accessory power (RAP) function that keeps comfort loads (windows, radio) powered for a s

View diagnosis
U3006Crítica

Control Module Input Power A Circuit/Open

Red (U)

Open circuit on the input power line A of the control module. The module is missing or losing its main supply

View diagnosis
U3007Crítica

Control Module Input Power B Circuit/Open

Red (U)

Open circuit on input power line B of the control module (second supply rail, e.g. permanent +12V vs switched

View diagnosis
U3008Crítica

Control Module Ground A

Red (U)

The control module detects a problem on its ground reference A — open ground, high resistance to chassis, or f

View diagnosis
U3009Crítica

Control Module Ground B

Red (U)

The control module detects a problem on its ground reference A — open ground, high resistance to chassis, or f

View diagnosis
U300AModerada

Ignition Switch

Red (U)

The control module detects an inconsistent or implausible ignition switch state — multiple positions reported

View diagnosis
U300BModerada

Ignition Input Accessory/On/Start

Red (U)

Fault on the combined ACC/ON/START ignition input line of the control module. A communication loss with this m

View diagnosis
U300CModerada

Ignition Input Off/On/Start

Red (U)

Fault on the OFF/ON/START ignition input line. A communication loss with this module breaks any function relyi

View diagnosis
U300DModerada

Ignition Input On/Start

Red (U)

Fault on the ON/START ignition input line — module sees inconsistent ON or START signal. A communication loss

View diagnosis
U300EModerada

Ignition Input On

Red (U)

Fault on the ignition ON input — module does not see ON state when other inputs say ON, or vice versa.

View diagnosis
U300FModerada

Ignition Input Accessory

Red (U)

Fault on the ignition ACC (accessory) input. A communication loss with this module breaks any function relying

View diagnosis
U3010Moderada

Ignition Input Start

Red (U)

Fault on the ignition START input — module does not see start request when cranking, or sees one when not cran

View diagnosis
U3011Moderada

Ignition Input Off

Red (U)

Fault on the ignition OFF input — module does not detect OFF state correctly. A communication loss with this m

View diagnosis
U3012Moderada

Control Module Improper Wake-up Performance

Red (U)

The control module did not wake up cleanly from sleep mode — wake event timing or sequence outside spec.

View diagnosis
U3013Crítica

Control Module Input Power C Circuit/Open

Red (U)

Open circuit on input power line C of the control module (third supply rail, e.g. for redundant power on safet

View diagnosis
U3014Crítica

Control Module Input Power D Circuit/Open

Red (U)

Open circuit on input power line D of the control module (fourth supply rail). A communication loss with this

View diagnosis
U3015Crítica

Control Module Ground C

Red (U)

Fault on the third ground reference of the module. A communication loss with this module breaks any function r

View diagnosis
U3016Crítica

Control Module Ground D

Red (U)

Fault on the fourth ground reference of the module. A communication loss with this module breaks any function

View diagnosis
U3017Moderada

Control Module Timer/Clock Performance

Red (U)

The control module's internal timer or clock has drifted or stopped — affects time-stamped diagnostic events,

View diagnosis