7355 código(s) en esta categoría. Página 202 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
Same as P245E with the signal in plausible range yet not matching the engine model.…
The DPF restriction has reached a level that forces the ECU to limit engine power. The driver must allow a for…
The DPF restriction has reached the limit defined for forced limited operation. Vehicle behaviour depends on t…
The DPF differential pressure sensor reports a backpressure rise consistent with excessive soot accumulation. …
The estimated soot mass in the DPF has crossed the upper limit and the ECU could not complete a regeneration t…
The differential pressure across the DPF exceeds the calibrated upper threshold during operation. Indicates se…
The DPF differential pressure sensor signal is implausible compared to engine load and exhaust flow. Either th…
A general circuit fault is detected on the EGT sensor at bank 2 sensor 3 (typically just downstream of the tur…
Same as P242B on bank 2 sensor 3.…
Same as P242C on bank 2 sensor 3. Wiring faults of this kind typically come from chafing, water ingress at con…
Same as P242D on bank 2 sensor 3. Wiring faults of this kind typically come from chafing, water ingress at con…
Same as P242E on bank 2 sensor 3. Wiring faults of this kind typically come from chafing, water ingress at con…
The driving pattern (short trips, low speed, frequent stops) does not provide the load and EGT needed for pass…
DPF backpressure on bank 2 is so high that the ECU enforces limp-home power limitation to protect the engine. …
The two DPF differential pressure sensors A and B disagree by more than the diagnostic tolerance - one of them…
A general circuit fault is detected on the EGT sensor at bank 1 sensor 4 (typically just downstream of the tur…
At cold start the SCR system is unable to begin reductant dosing within the required time. Typical cause on di…
The exhaust gas temperature sensor 3 on bank 1 (often after the DPF) shows intermittent dropouts. Erratic read…
EGT sensor 3 on bank 1 reports values that are not plausible for current operating conditions. Either drift or…
The voltage from EGT sensor 3 on bank 1 is below the calibrated minimum. The signal indicates either a short t…
The voltage of EGT sensor 3 on bank 1 is above the calibrated maximum. Often a sign of an open sensor circuit …
Same as P242B on bank 2 sensor 4.…
Same as P242C on bank 2 sensor 4. Wiring faults of this kind typically come from chafing, water ingress at con…
Same as P242D on bank 2 sensor 4. Wiring faults of this kind typically come from chafing, water ingress at con…