7355 código(s) en esta categoría. Página 223 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
The rocker arm actuator A on bank 2 stays in the activated state when commanded off.…
Voltage on the rocker arm actuator A control line on bank 2 is below the expected window. Usually a short to g…
Voltage on the rocker arm actuator A control line on bank 2 is above the expected window. Typical causes are a…
The position sensor that confirms the B rocker arm switching state on bank 1 returns no usable signal.…
The position sensor reading does not transition cleanly between the two valve lift modes for actuator B on ban…
The position sensor signal for actuator B on bank 1 is below the lower diagnostic threshold. Wiring faults of …
The position sensor signal for actuator B on bank 1 is above the upper diagnostic threshold. Wiring faults of …
The position sensor signal for actuator B on bank 1 jumps or drops out intermittently. Usually a loose connect…
The variable-displacement A/C compressor control valve does not respond to commands within tolerance. Refriger…
The controller cannot drive the rocker arm switching actuator B on bank 2.…
The rocker arm actuator B on bank 2 is commanded to engage but does not switch.…
The rocker arm actuator B on bank 2 stays in the activated state when commanded off.…
Voltage on the rocker arm actuator B control line on bank 2 is below the expected window. Usually a short to g…
Voltage on the rocker arm actuator B control line on bank 2 is above the expected window. Typical causes are a…
The controller cannot drive the secondary fuel shutoff valve. Engine cannot be commanded off through this path…
Voltage on the secondary fuel shutoff valve control line is below the expected window. Usually a short to grou…
Voltage on the secondary fuel shutoff valve control line is above the expected window. Typical causes are a sh…
The fuel mode indicator lamp circuit (showing whether a bi-fuel vehicle currently runs on gasoline or alternat…
The second power feed used to supply actuators (relays, solenoids, motor drivers) is open. All loads on this r…
The position sensor that confirms the A rocker arm switching state on bank 2 returns no usable signal.…
The position sensor reading does not transition cleanly between the two valve lift modes for actuator A on ban…
The position sensor signal for actuator A on bank 2 is below the lower diagnostic threshold. Wiring faults of …
The position sensor signal for actuator A on bank 2 is above the upper diagnostic threshold. Wiring faults of …
The position sensor signal for actuator A on bank 2 jumps or drops out intermittently. Wiring faults of this k…