7355 código(s) en esta categoría. Página 236 de 307. Selecciona uno para ver el diagnóstico detallado.
Motor (P)
Voltage on the gate-select direction line is below the expected window. Wiring faults of this kind typically c…
Voltage on the gate-select direction line is above the expected window. Wiring faults of this kind typically c…
The gear-shift direction circuit cannot detect the commanded shift direction (up or down) on an automated manu…
Voltage on the gear-shift direction line is below the expected window. Wiring faults of this kind typically co…
Voltage on the gear-shift direction line is above the expected window. Wiring faults of this kind typically co…
The controller cannot drive the first auxiliary transmission fluid pump. Pressure is lost during stop-start en…
The first auxiliary transmission fluid pump is commanded on but does not run.…
Voltage on the first auxiliary transmission fluid pump control line is below the expected window. Wiring fault…
Voltage on the first auxiliary transmission fluid pump control line is above the expected window. Wiring fault…
When the transfer case is in High range the measured input/output speed ratio does not match the expected valu…
When the transfer case is in Low range the measured input/output speed ratio does not match the expected value…
When the transfer case is in Neutral the measured output speed is not zero or shows unexpected drag.…
The 4WD range signal circuit (reporting whether 2H, 4H, 4L is engaged) returns no usable signal.…
The 4WD range signal does not match expected value for the commanded transfer case position. Wiring faults of …
Voltage on the 4WD range signal line is below the expected window. Wiring faults of this kind typically come f…
Voltage on the 4WD range signal line is above the expected window. Wiring faults of this kind typically come f…
The first auxiliary transmission fluid pump runs even when no command is active.…
The controller cannot drive the second auxiliary transmission fluid pump.…
The second auxiliary transmission fluid pump is commanded on but does not run.…
Voltage on the second auxiliary transmission fluid pump control line is below the expected window. Wiring faul…
Voltage on the second auxiliary transmission fluid pump control line is above the expected window. Wiring faul…
The second auxiliary transmission fluid pump runs even when no command is active.…
The calibration data programmed for pressure control solenoid A does not match the format expected by the tran…
The calibration data programmed for pressure control solenoid B does not match the format expected by the tran…