7355 code(s) in this category. Page 51 of 307. Select one to see the detailed diagnosis.
Motor (P)
Same as P04B3 with the valve stuck closed - vapor cannot reach the canister during refueling, vapor escape fro…
On vehicles with a motorised fuel fill door (no manual lever) the actuator and position switch report that the…
Same as P04B5 with the door stuck closed - the user cannot refuel until the fault is cleared.…
The position sensor or switch on the fuel fill door reports an intermittent signal - opens and closes randomly…
A general circuit fault is detected on the fuel fill door position sensor or switch - the ECU cannot determine…
Same as P04B8 with the signal voltage below the plausible range. Wiring faults of this kind typically come fro…
Same as P04B8 with the signal voltage above the plausible range. Wiring faults of this kind typically come fro…
The fuel fill door has a powered lock that secures it against tampering and against opening at high speed. The…
The fuel fill door lock does not respond as commanded - lock or unlock requests do not match the position feed…
Same as P04BB with the control line shorted to ground. Wiring faults of this kind typically come from chafing,…
Same as P04BB with the control line shorted to supply. Wiring faults of this kind typically come from chafing,…
Same as P04BD on the unlock side. Wiring faults of this kind typically come from chafing, water ingress at con…
Same as P04BE on the unlock side. Wiring faults of this kind typically come from chafing, water ingress at con…
A general circuit fault is detected on the fuel fill door lock position sensor or switch. Without it the ECU c…
Same as P04C3 with feedback in plausible range yet not matching the commanded lock state.…
Same as P04C3 with the signal voltage below the plausible range. Wiring faults of this kind typically come fro…
Same as P04C3 with the signal voltage above the plausible range. Wiring faults of this kind typically come fro…
Same as P04C3 with intermittent feedback. Wiring faults of this kind typically come from chafing, water ingres…
A general circuit fault is detected on the open-request input - the button or switch the driver presses to rel…
The open-request switch never registers an active state - either the contact stays open mechanically or the wi…
Same as P04C8 with the signal voltage shorted to ground or constantly low. Wiring faults of this kind typicall…
Same as P04C8 with the signal voltage shorted to supply or constantly high. Wiring faults of this kind typical…