Skip to content
PPowertrain (P)

Codes Powertrain (P)

7355 code(s) in this category. Page 7 of 307. Select one to see the detailed diagnosis.

P0091Crítica

Fuel Pressure Regulator A Control Circuit Low

Motor (P)

Fuel pressure regulator A control voltage below expected range — short to ground. Wiring faults of this kind t

View diagnosis
P0092Crítica

Fuel Pressure Regulator A Control Circuit High

Motor (P)

Fuel pressure regulator A control voltage above expected range — short to power or open ground. Wiring faults

View diagnosis
P0093Crítica

Fuel System Leak Detected - Large Leak

Motor (P)

The ECU detected a large leak in the fuel system. Rail pressure cannot be maintained, often visible as fuel od

View diagnosis
P0094Moderada

Fuel System Leak Detected - Small Leak

Motor (P)

A small fuel system leak detected by long-term pressure drop pattern. Often a slowly weeping injector or hairl

View diagnosis
P0095Moderada

Intake Air Temperature Sensor 2 Circuit Bank 1

Motor (P)

Generic electrical fault on intake air temperature sensor 2 (typically post-intercooler) on bank 1. The intake

View diagnosis
P0096Moderada

Intake Air Temperature Sensor 2 Circuit Range/Performance Bank 1

Motor (P)

IAT sensor 2 reading on bank 1 is electrically valid but implausible — does not match other temperature source

View diagnosis
P0097Moderada

Intake Air Temperature Sensor 2 Circuit Low Bank 1

Motor (P)

IAT sensor 2 bank 1 signal voltage below expected range — short to ground. The intake air temperature sensor f

View diagnosis
P0098Moderada

Intake Air Temperature Sensor 2 Circuit High Bank 1

Motor (P)

IAT sensor 2 bank 1 signal voltage above expected range — open circuit or short to power. The intake air tempe

View diagnosis
P0099Moderada

Intake Air Temperature Sensor 2 Circuit Intermittent/Erratic Bank 1

Motor (P)

Intermittent dropouts or noise on IAT sensor 2 bank 1 signal. The intake air temperature sensor feeds the ECM'

View diagnosis
P009AModerada

Intake Air Temperature/Ambient Air Temperature Correlation

Motor (P)

Intake air temperature and ambient air temperature readings deviate beyond plausible limits — at engine off bo

View diagnosis
P009BModerada

Fuel Pressure Relief Control Circuit/Open

Motor (P)

Open circuit at fuel pressure relief solenoid (used to bleed off rail pressure during certain operating modes)

View diagnosis
P009CModerada

Fuel Pressure Relief Control Circuit Low

Motor (P)

Pressure relief solenoid control voltage below expected range — short to ground. Wiring faults of this kind ty

View diagnosis
P009DModerada

Fuel Pressure Relief Control Circuit High

Motor (P)

Pressure relief solenoid control voltage above expected range — short to power or open ground. Wiring faults o

View diagnosis
P009EModerada

Fuel Pressure Relief Control Performance/Stuck Off

Motor (P)

Pressure relief solenoid does not relieve pressure when commanded — stuck closed.

View diagnosis
P009FCrítica

Fuel Pressure Relief Control Stuck On

Motor (P)

Pressure relief solenoid stays open when not commanded — rail pressure cannot build up properly.

View diagnosis
P00A0Moderada

Charge Air Cooler Temperature Sensor Circuit Bank 2

Motor (P)

Generic electrical fault on charge air cooler temperature sensor on bank 2. Same as P007A on bank 2.

View diagnosis
P00A1Moderada

Charge Air Cooler Temperature Sensor Circuit Range/Performance Bank 2

Motor (P)

CAC temperature sensor reading on bank 2 implausible. Same as P007B on bank 2. Wiring faults of this kind typi

View diagnosis
P00A2Moderada

Charge Air Cooler Temperature Sensor Circuit Low Bank 2

Motor (P)

Charge air cooler temperature sensor signal voltage on bank 2 below expected range. Typically a short to groun

View diagnosis
P00A3Moderada

Charge Air Cooler Temperature Sensor Circuit High Bank 2

Motor (P)

Charge air cooler temperature sensor signal voltage on bank 2 above expected range. Typically open circuit or

View diagnosis
P00A4Moderada

Charge Air Cooler Temperature Sensor Circuit Intermittent/Erratic Bank 2

Motor (P)

Intermittent dropouts or noise on the charge air cooler temperature sensor signal on bank 2. Wiring faults of

View diagnosis
P00A5Moderada

Intake Air Temperature Sensor 2 Circuit Bank 2

Motor (P)

Generic electrical fault on intake air temperature sensor 2 (typically post-intercooler) on bank 2. The intake

View diagnosis
P00A6Moderada

Intake Air Temperature Sensor 2 Circuit Range/Performance Bank 2

Motor (P)

IAT sensor 2 reading on bank 2 is electrically valid but implausible — does not match other temperature source

View diagnosis
P00A7Moderada

Intake Air Temperature Sensor 2 Circuit Low Bank 2

Motor (P)

IAT sensor 2 bank 2 signal voltage below expected range — short to ground. The intake air temperature sensor f

View diagnosis
P00A8Moderada

Intake Air Temperature Sensor 2 Circuit High Bank 2

Motor (P)

IAT sensor 2 bank 2 signal voltage above expected range — open circuit or short to power. The intake air tempe

View diagnosis